LAB REPORTS, EXPLAINED
How to Read a COA
A COA (Certificate of Analysis) is the lab’s report on one batch. Here is what each part means, so you can check any report yourself in about a minute.
The 5 things to check first
1The batch number matches your vial
Every vial label has a batch number that starts with PLR. The report should show the same batch, or you can type it into our batch lookup to pull up the right report.
2The lab is independent
The report is issued by the lab, not by us. Look for the lab’s name, logo and report number at the top.
3Identity says the right compound
The lab confirms the material is the compound on the label, usually by mass spectrometry. It should read as a match or pass.
4Purity and amount
Purity (by HPLC) shows how much of the sample is the target compound. Amount, also called net content, shows how many milligrams the lab measured in the vial compared with the label.
5You can verify it on the lab’s website
Most reports include a QR code, a verification link or an access code. Use it on the lab’s own site to confirm the report is real and unchanged.
Every test, in plain words
| Test | What it tells you | What a good result looks like |
|---|---|---|
| Identity | The vial contains the compound on the label. | Match / pass |
| Purity | How much of the sample is the target compound vs. impurities. | A high percentage, shown with the method (HPLC) |
| Amount (net content) | How many milligrams were measured in the vial. | Close to, or above, the amount on the label |
| Endotoxin | Checks for bacterial endotoxins, which can remain even after bacteria are gone. | Below the lab’s limit, or pass |
| Sterility | Checks for microbial growth or microbial DNA. | No growth / not detected |
| Heavy metals | Screens for arsenic, cadmium, lead and mercury. | Below the lab’s limits, or pass |
| Fentanyl screen | Screens the sample for fentanyl contamination. | Not detected |
| Vial-to-vial consistency | More than one vial from the same batch was tested and compared. | Results that closely match each other |
Words you will see on a report
HPLC – the method most labs use to measure purity.
MS / LC-MS – mass spectrometry, used to confirm identity.
EU/mg or EU/mL – the unit used for endotoxin results.
LOD / LOQ – the smallest amount the lab’s method can detect or measure. “Below LOD” means nothing was found.
ND – not detected.
Red flags on any company’s COA
No batch number, or a batch like “NA” that can’t be matched to a vial.
No way to verify the report on the lab’s website.
The same report used for many different batches or products.
Only a purity number, with no identity or amount result.
All products are sold for laboratory research use only. Not for human or veterinary use.